Selecting the Stability Function:
This function determines if the input values from the sensor are stable. This function requires that you enter in both
a stability time and stability count. If the difference between the current indicated value and the previous value (2.5
msec before) is less than the set count (determined by the number you enter for the stability count) and the duration of
the condition is more then the set time (determined by the time you entered for the stability time), the indicated value
is regarded as stable.
- Press the Mode button
- Select the 'OPERATIONS' tag
- Select the Stability (Time) button and enter in your desired time.
Press the OK button and you will be back in the 'OPERATIONS' menu
- Select the Stability (Cnt) button and enter in your desired count.
Press the OK button and you will be back in the operations menu
- Press the HOME button to return to the run mode
|
|