The QLA167 is a custom milligram load cell designed for applications whose measurement range is from 0 to 10 grams.
This load cell is optimized for ultra-low capacity compression applications and features resolution in the milligram range.
For reliable measurements, the QLA167 milligram load cell is equipped with axial overload protection and
it is resistant to side loads. Its integrated cable with robust mechanical strain relief makes this sensor suitable for
applications with dynamic movement.
Its rated measurement range is 10 grams (i.e. 10g load cell).
CHANNEL | MIN | TYP | MAX | UNIT | |
---|---|---|---|---|---|
Input Resistance | 1 | 1060 | Ohms nom. | ||
Safe Overload | 1 | 150 | % of R.O. | ||
Capacity | 1 | 10 | Gram | ||
Hysteresis | 1 | -0.1 | 0.1 | % of R.O. | |
Nonlinearity | 1 | -0.25 | 0.25 | % of R.O. | |
Output Resistance | 1 | 1000 | Ohms nom. | ||
Rated Output | 1 | 0.5 | 1 | 1 | mV/V nom. |
Compensated Temperature | 1 | 60 | 160 | F | |
Operating Temperature | 1 | -60 | 200 | F | |
Temperature Shift Span | 1 | -0.005 | 0.005 | % of Load/F | |
Temperature Shift Zero | 1 | -0.005 | 0.005 | % of R.O./F |