QLA399 play_arrowQSH01841

Parallelogram Load Cell with High Resolution RS232 Output

QLA399, 300 g , Digital OEM Load Cell Scale w/ High Resolution RS232 Output , Material 2024-T4 , #10-32-Thread , Overload Protection , 6 Pin Molex Connector
inStockimg
In Stock
Listed price is in U.S. currency and subject to verification along with availability
QLA399
QLA399
Description

Parallelogram Load Cell with High Resolution RS232 Output

Features
Specifications
Calibration
Electrical
Mechanical
Performance
Temperature
CHANNELMINTYPMAXUNIT
Calibration Excitation
1
24
Vdc
Excitation
1
24
Vdc
Safe Overload
1
5000
% of R.O.
Capacity
1
300
Gram
Nonlinearity
1
-0.05
0.05
% of R.O.
Nonrepeatability
1
-0.05
0.05
% of R.O.
Rated Output
1
100
Gram
Compensated Temperature
1
60
160
F
Operating Temperature
1
60
160
F
Temperature Shift Span
1
-0.01
0.01
% of Load/F
Temperature Shift Zero
1
-0.01
0.01
% of R.O./F